Telford Tempest Indirect 400L Horizontal Unvented Hot Water Cylinder TSMI400H
The Telford Tempest Indirect 400L Horizontal Unvented Hot Water Cylinder provides dependable mains pressure domestic hot water for properties where a conventional vertical cylinder cannot be accommodated.
Designed for use with compatible gas or oil-fired boilers, this 400-litre horizontal cylinder incorporates an internal stainless steel heating coil that transfers heat from the boiler’s primary heating circuit into the stored domestic hot water.
Manufactured from durable Duplex stainless steel, the Telford Tempest TSMI400H combines corrosion-resistant construction, effective insulation and generous hot water storage.
Its horizontal design makes it particularly suitable for appropriately designed low-height plant rooms and other installations with restricted headroom. The installation location must be capable of safely supporting the full operating weight of the cylinder.
A factory-fitted 3kW electric immersion heater provides supplementary or backup hot water heating when required.
Key Features & Benefits
- 400 Litre Capacity – Generous domestic hot water storage for properties with substantial hot water requirements.
- Horizontal Installation – Designed for installations where a conventional upright cylinder is impractical.
- Indirect Boiler Heating – Internal stainless steel coil transfers heat from a compatible gas or oil-fired boiler.
- 3kW Immersion Backup – Factory-fitted electric immersion heater provides an alternative hot water heating source.
- Duplex Stainless Steel – Durable, corrosion-resistant cylinder construction.
- Mains Pressure Hot Water – Supplies pressurised hot water to taps and showers, subject to adequate incoming mains pressure and flow.
- 45-Minute Reheat Time – Manufacturer-declared indirect reheat performance under specified test conditions.
- High-Performance Insulation – Helps minimise standing heat loss and maintain stored water temperature.
- ErP C Energy Rating – Manufacturer-declared energy efficiency class C.
- Horizontal Dimensions – Measures 1590mm long and 660mm in diameter.
- Support Cradles Included – Designed to support the cylinder in its intended horizontal position.
- Unvented Installation Kit – Supplied with essential safety and installation components.
- Manufacturer’s Guarantee – Lifetime cover on the cylinder body and 2 years on components, subject to terms.
Technical Specifications
| Specification | Details |
|---|---|
| Manufacturer | Telford |
| Product Range | Tempest Indirect Horizontal |
| Model / SKU | TSMI400H |
| Nominal Capacity | 400 Litres |
| Actual Capacity | 391 Litres |
| Cylinder Type | Indirect Unvented |
| Installation Orientation | Horizontal |
| Primary Heat Source | Compatible Gas or Oil Boiler |
| Heat Exchanger | Internal Stainless Steel Coil |
| Backup Heating | Electric Immersion |
| Immersion Heater | 1 × 3kW, 240V |
| Cylinder Material | Duplex Stainless Steel |
| Cylinder Length | 1590mm |
| Cylinder Diameter | 660mm |
| Height Including Supports | 760mm* |
| Empty Weight | 68kg |
| Full Weight | 459kg |
| ErP Energy Rating | C |
| Standing Heat Loss | 2.42 kWh/24h (101W) |
| Reheat Time (10–60°C) | 45 Minutes** |
| Operating Pressure | 3 Bar |
| Maximum Incoming Supply Pressure | 12 Bar |
| Domestic & Primary Connections | 1-inch female connections |
| Cylinder Guarantee | Lifetime*** |
| Component Guarantee | 2 Years*** |
*Manufacturer’s drawing dimension B. Allow additional clearance for pipework, connections, access and servicing.
**Reheat time is measured using the indirect boiler heating coil under manufacturer-specified conditions, not the immersion heater.
***Manufacturer’s guarantee terms and conditions apply.
What’s Included?
- Telford Tempest Indirect 400L Horizontal cylinder
- Internal stainless steel boiler heating coil
- Factory-fitted 3kW electric immersion heater
- Factory-fitted temperature and pressure relief valve
- External expansion vessel with mounting bracket
- Inlet control group
- Two-port motorised valve
- Dual-probe thermostat
- Acetal tundish
- Horizontal support cradles
- Unvented installation component kit
Suitable For
- Properties with substantial domestic hot water requirements
- Buildings with restricted cylinder installation height
- Suitable low-height plant rooms and utility spaces
- Homes using compatible gas or oil-fired boilers
- Replacement of compatible horizontal indirect cylinders
- Properties requiring mains pressure hot water
- Installations where a standard vertical cylinder is impractical
Warranty Information
The Telford Tempest Indirect 400L Horizontal Cylinder includes a lifetime manufacturer’s guarantee on the cylinder body and a 2-year guarantee on components, subject to Telford’s terms and conditions.
Annual servicing by a suitably qualified professional is important for safe operation and maintaining applicable warranty cover.
Installation must be carried out by a suitably qualified professional, with suitable structural support, unvented safety controls, discharge pipework and maintenance access.
Buy the Telford Tempest Indirect 400L Horizontal Unvented Hot Water Cylinder (TSMI400H) from BoilersnBits for durable stainless steel construction, dependable boiler-fed hot water storage and space-saving horizontal installation.